Western blot protocol

Procedure for western blotting

Solutions and reagents:

Lysis buffers

These buffers may be stored at 4°C for several weeks or for up to a year aliquoted and stored at -20°C.

RIPA buffer (Sigma #R0278)
Complete Protease Inhibitor cocktail (Roche #)

PhosSTOP Phosphatase inhibitor Cocktail (Roche #)


1xTBS buffer
20 mM Tris-HCl

150 mM NaCl

Milli-Q Water

pH 7.5

1xTBST buffer

1xTBS buffer

0.1% (v/v) Tween-20

pH 7.5


Running Buffer

100 ml 10x Tris/Glycine/SDS (Bio-Rad #161-0732)

900 ml Milli-Q water


Transfer Buffer

100 ml 10x Tris/Glycine (Bio-Rad #161-0734)

200 ml methanol

700 ml Milli-Q water


Blocking buffer

5% (w/v) milk

Add to TBS buffer. Mix well.


Antibody dilution buffer
5% (w/v) milk

Add to TBST buffer. Mix well.


Procedure:

1. Sample lysis

Preparation of lysate from cell culture

1.     Place the cell culture dish in ice and wash the cells with ice-cold PBS.

2.     Aspirate the PBS, then add ice-cold lysis buffer (1 ml per 107 cells/100 mm dish/150 cm2   flask; 0.5ml per 5x106 cells / 60 mm dish / 75 cm2 flask).

3.     Scrape adherent cells off the dish using a cold plastic cell scraper, then gently transfer the cell suspension into a pre-cooled microcentrifuge tube.

4.     Maintain constant agitation for 30 minutes at 4°C.

5.     Sonicate for 1 minutes (2 seconds working and 3 seconds rest for each cycle)

6.     Spin at 16,000 x g for 20 minutes in a 4°C pre-cooled centrifuge.

7.     Gently remove the tube from the centrifuge and place on ice. Transfer the supernatant to a fresh tube kept on ice, and discard the pellet.

2. Sample preparation

1.     Determine the protein concentration for each cell lysate. (Appendix 1)

2.     To the remaining volume of cell lysate, adjust the concentration of cell lysate at 1 ug/ul with lysis buffer, 4xSample Buffer (Invitrogen # NP0007) and 10xSample Reducing Agent (Invitrogen # NP0009).

3.     To reduce and denature: Boil each cell lysate in sample buffer at 100°C for 5 minutes and aliquot. Store lysates at -20°C. Note: aliquot cell lysates (50- 100 μl) to avoid repeat freeze/thaw cycles.

4.     Defrost tubes containing cell lysate at 37°C. Centrifuge at 16,000 x g in a microcentrifuge for 5 minutes.

3. Loading and running the gel

1.     Load equal amounts of protein into the wells of the SDS-PAGE gel (Bio-Rad # 567-1085), along with molecular weight markers. Load 10- 40 μg of total protein from cell lysate.

2.     Run the gel for 1 to 2 hours at 100 V.

4. Transferring the protein from the gel to the membrane

  1. Cut off nick top left-hand corner of resolving gel for orientation.
  2. Measure the dimensions of the gel and note the positions of the ladder bands.
  3. Transfer gel, while still attached to glass plate, to box containing TGM and peel off gently with a spatula.
  4.  Agitate 15-20 seconds at RT to remove salts and SDS.
  5. Cut a piece of PVDF membrane to the size of the gel and mark and/or clip one corner as the top left-hand corner. Handle only with flat forceps.
  6. Immerse membrane in Transfer buffer for 10-15 seconds.
  7. Cut 2 pieces of >3mm filter paper to the dimensions of the gel (or slightly bigger).
  8. Open a gel holder cassette in a casserole dish, black side down and hinges to the left and below the black side.
  9. Soak a fiber pad with Transfer buffer and place in the center of the black side.
  10. Soak one piece of filter paper with Transfer buffer and place on top of the fiber pad.
  11. Roll out bubbles with glass tube and add 3ml of Transfer buffer onto the top.
  12. Place gel on top of filter paper.
  13. Roll out bubbles with glass tube and add 3ml of Transfer buffer onto the top.
  14. Place membrane on top of gel, with the gel’s top left mark facing the membrane’s top left mark.
  15. Roll out bubbles with glass tube and add 3ml of Transfer buffer onto the top.
  16. Soak a second piece of filter paper with Transfer buffer and place on top of the membrane.
  17. Roll out bubbles with glass tube and add 3ml of Transfer buffer onto the top.
  18. Soak a second piece of fiber pad and place on top of stack.
  19. Roll out bubbles with glass tube and add 3ml of Transfer buffer onto the top.
  20. Close the gel holder cassette.
  21. Place in a transfer tank (orient the red and black sides of the cassette with the red and black panels of the electrode) and fill with Transfer buffer (~2000ml).
  22. Place the tank in a styrofoam box containing ice.
  23. Run 75 minutes at 100V.

5. Antibody staining

1.     Block the membrane for 1-2 hours at room temperature using 5% blocking solution.

2.     Incubate membrane with appropriate dilutions of primary antibody (Appendix 2) in antibody dilution buffer overnight at 4°C.

3.     Wash the membrane in three washes of 1xTBST, 5 minutes each.

4.     Incubate the membrane with the recommended dilution of labeled secondary antibody in antibody dilution buffer at room temperature for 1 hour.

5.     Wash the membrane in three washes of 1xTBST, 5 minutes each, then rinse in 1xTBS.

6.     Scan the membrane according to the manual of Obyssey.




Appendix 1

Preparation of Standards and Working Reagent

A. Preparation of Diluted Albumin (BSA) Standards

Use Table 1 as a guide to prepare a set of protein standards. Dilute the contents of one Albumin Standard (BSA) ampule into several clean vials, preferably using the same diluent as the sample(s). Each 1mL ampule of 2mg/mL Albumin Standard is sufficient to prepare a set of diluted standards for either working range suggested in Table 1. There will be sufficient volume for three replications of each diluted standard. Table 1. Preparation of Diluted Albumin (BSA) Standards

Dilution Scheme for Standard Test Tube Protocol and Microplate Procedure (Working Range = 20-2,000μg/mL)

Vial

Volume of Diluent

(μL)

Volume and Source of BSA (μL)

Final BSA Concentration (μg/mL)

A

0

300 of Stock

2000

B

125

375 of Stock

1500

C

325

325 of Stock

1000

D

175

175 of vial B dilution

750

E

325

325 of vial C dilution

500

F

325

325 of vial E dilution

250

G

325

325 of vial F dilution

125

H

400

100 of vial G dilution

25

I

400

0

0 = Blank

B. Preparation of the BCA Working Reagent (WR)

1. Use the following formula to determine the total volume of WR required:

(# standards + # unknowns) × (# replicates) × (volume of WR per sample) = total volume WR required

Example: for the standard test-tube procedure with 3 unknowns and 2 replicates of each sample:

(9 standards + 3 unknowns) × (2 replicates) × (2mL) = 48mL WR required

Note: 2.0mL of the WR is required for each sample in the test-tube procedure, while only 200 μl of WR reagent is required for each sample in the microplate procedure.

2. Prepare WR by mixing 50 parts of BCA Reagent A with 1 part of BCA Reagent B (50:1, Reagent A:B). For the above example, combine 50mL of Reagent A with 1mL of Reagent B.

Note: When Reagent B is first added to Reagent A, turbidity is observed that quickly disappears upon mixing to yield a clear, green WR. Prepare sufficient volume of WR based on the number of samples to be assayed. The WR is stable for several days when stored in a closed container at room temperature (RT).

Microplate Procedure (Sample to WR ratio = 1:8)

1. Pipette 25μL of each standard or unknown sample replicate into a microplate well (working range = 20-2000μg/mL).

Note: If sample size is limited, 10μL of each unknown sample and standard can be used (sample to WR ratio = 1:20). However, the working range of the assay in this case will be limited to 125-2000μg/mL.

2. Add 200μL of the WR to each well and mix plate thoroughly on a plate shaker for 30 seconds.

3. Cover plate and incubate at 37°C for 30 minutes.

4. Cool plate to RT. Measure the absorbance at or near 562nm on a plate reader.


 

 

化工儀器網

推薦收藏該企業網站
主站蜘蛛池模板: ERP企业管理系统永久免费版_在线ERP系统_OA办公_云版软件官网 | 包装设计公司,产品包装设计|包装制作,包装盒定制厂家-汇包装【官方网站】 | 压砖机、液压制砖机、静压砖机、环保砖机生产厂家—杜甫机械 | 农产品溯源系统_农产品质量安全追溯系统_溯源系统 | 无线联网门锁|校园联网门锁|学校智能门锁|公租房智能门锁|保障房管理系统-KEENZY中科易安 | 全自动真空上料机_粉末真空上料机_气动真空上料机-南京奥威环保科技设备有限公司 | 二手Sciex液质联用仪-岛津气质联用仪-二手安捷伦气质联用仪-上海隐智科学仪器有限公司 | 粉末冶金-粉末冶金齿轮-粉末冶金零件厂家-东莞市正朗精密金属零件有限公司 | 济南拼接屏_山东液晶拼接屏_济南LED显示屏—维康国际官网 | 选宝石船-陆地水上开采「精选」色选机械设备-青州冠诚重工机械有限公司 | 屏蔽泵厂家,化工屏蔽泵_维修-淄博泵业 | 全自动变压器变比组别测试仪-手持式直流电阻测试仪-上海来扬电气 | 一体化净水器_一体化净水设备_一体化水处理设备-江苏旭浩鑫环保科技有限公司 | 济南品牌包装设计公司_济南VI标志设计公司_山东锐尚文化传播 | 全自动在线分板机_铣刀式在线分板机_曲线分板机_PCB分板机-东莞市亿协自动化设备有限公司 | 高楼航空障碍灯厂家哪家好_航空障碍灯厂家_广州北斗星障碍灯有限公司 | 衡阳耐适防护科技有限公司——威仕盾焊接防护用品官网/焊工手套/焊接防护服/皮革防护手套 | 断桥铝破碎机_铝合金破碎机_废铁金属破碎机-河南鑫世昌机械制造有限公司 | 玉米深加工设备|玉米加工机械|玉米加工设备|玉米深加工机械-河南成立粮油机械有限公司 | 高楼航空障碍灯厂家哪家好_航空障碍灯厂家_广州北斗星障碍灯有限公司 | 重庆私家花园设计-别墅花园-庭院-景观设计-重庆彩木园林建设有限公司 | 培训一点通 - 合肥驾校 - 合肥新亚驾校 - 合肥八一驾校 | 济宁工业提升门|济宁电动防火门|济宁快速堆积门-济宁市统一电动门有限公司 | 金属管浮子流量计_金属转子流量计厂家-淮安润中仪表科技有限公司 | hc22_hc22价格_hc22哈氏合金—东锜特殊钢 | 氧化锆纤维_1800度高温退火炉_1800度高温烧结炉-南京理工宇龙新材料股份有限公司 | 口信网(kousing.com) - 行业资讯_行业展会_行业培训_行业资料 | 上海道勤塑化有限公司| 锂离子电池厂家-山东中信迪生电源| 岛津二手液相色谱仪,岛津10A液相,安捷伦二手液相,安捷伦1100液相-杭州森尼欧科学仪器有限公司 | Dataforth隔离信号调理模块-信号放大模块-加速度振动传感器-北京康泰电子有限公司 | 南溪在线-南溪招聘找工作、找房子、找对象,南溪综合生活信息门户! | 二氧化碳/活性炭投加系统,次氯酸钠发生器,紫外线消毒设备|广州新奥 | 水性漆|墙面漆|木器家具漆|水漆涂料_晨阳水漆官网 | 硅胶制品-硅橡胶制品-东莞硅胶制品厂家-广东帝博科技有限公司 | 考勤系统_考勤管理系统_网络考勤软件_政企|集团|工厂复杂考勤工时统计排班管理系统_天时考勤 | 塑钢件_塑钢门窗配件_塑钢配件厂家-文安县启泰金属制品有限公司 深圳南财多媒体有限公司介绍 | 洁净化验室净化工程_成都实验室装修设计施工_四川华锐净化公司 | 液压升降平台_剪叉式液压/导轨式升降机_传菜机定做「宁波日腾升降机厂家」 | 电机铸铝配件_汽车压铸铝合金件_发动机压铸件_青岛颖圣赫机械有限公司 | 山东活动策划|济南活动公司|济南公关活动策划-济南锐嘉广告有限公司 |